• Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
  • Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
  • Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
  • Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
  • Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
  • Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump

Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump

Max.Capacity: <50 L/min
Pressure Medium: Liquid
Certification: CE, ISO
Standard or Non: Standard
Theory: Reciprocating Pump
Power: Pneumatic
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DGGD40
Voltage
220V
Structure
Piston Pump
Usage
Air Driven
Material
Stainless Steel
Boost Ratio
40:1
Certificate
ISO/Ce
Transport Package
1 Set/Case by Plywood Case
Trademark
SUNCENTER
Origin
China
HS Code
8413501090
Production Capacity
500 Sets/Month

Product Description

Suncenter DGGD40 0-320BAR Air Driven Chemical Liquid Injection Booster Pump


SUNCENTER pumps are air driven at a drive air pressure of 1bar to 8bar (14.5 psi to116 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.
Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.

Applications include:
  1.  Pressure testing
  2.  Burst(Hydrostatic) testing
  3.  Work holding/power clamping
  4.  Jacking/lifting
  5.  Valve actuator control
  6.  Hydraulic cylinder actuation
  7.  Press safety overload devices
  8.  Roller tensioning
  9.  Metering
  10.  Precision lubrication and spraying
  11.  Liquefied gas transfer


Key features include:
  1. Compressed Air driven - no electricity required (connect to normal air compressor)
  2. In order to extend the lifetime of the pump, the driving air pressure should
not be higher than 8 bar
  1. No airline lubricator required
  2. Pressures to 640Mpa (6400 bar) 
  3. Wide range of models with different ratios
  4. Built-in-cooling on most models
  5. Easy to install, operate and maintain
  6. Best price / performance ratio
  7. No heat, flame or spark risk and explosion proof
  8. Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

DGGD Series Liquid Pumps(Double acting, single air drive head)
They are characterized by the same features as the DGG pumps single acting, single air drive head types,
but they have less pulsations and deliver approx. 50 % more flow.

Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
Technical specification
 
Model Pressure  Boost Ratio Driven air pressure PL Formula to calculate outlet pressure MAX Outlet
Pressure(bar)*
Liquid inlet Connection Liquid outlet Connection MAX Flow (L/min)**
DGGD4 4:1 2-8 bar 4XPL 32 NPT1/2 NPT1/2 70.00
DGGD6 6:1 2-8 bar 6XPL 48 NPT1/2 NPT1/2 48.60
DGGD10 10:1 2-8 bar 10XPL 80 NPT1/2 NPT1/2 30.61
DGGD16 16:1 2-8 bar 16XPL 128 NPT1/2 NPT1/2 19.73
DGGD28 28:1 2-8 bar 28XPL 224 NPT1/2 NPT1/2 11.30
DGGD40 40:1 2-8 bar 40XPL 320 NPT1/2 NPT3/8 7.69
DGGD64 64:1 2-8 bar 64XPL 512 NPT1/2 NPT3/8 4.94
DGGD80 80:1 2-8 bar 80XPL 640 NPT1/2 NPT3/8 3.96
DGGD100 100:1 2-8 bar 100XPL 800 NPT1/2 NPT3/8 3.13
DGGD130 130:1 2-8 bar 130XPL 1040 NPT1/2 M14*1.5 2.40
DGGD175 175:1 2-8 bar 175XPL 1400 NPT3/8 M14*1.5 1.81
DGGD255 255:1 2-8 bar 255XPL 2040 NPT1/4 M14*1.5 1.23
DGGD400 400:1 2-8 bar 400XPL 3200 NPT1/4 M14*1.5 0.79

The outlet liquid pressure=Driven air pressure*boost ratio
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar



SUNCENTER pumps are self priming. In general it is not necessary to use an air line lubricator.
The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction effect, the inlet check valve is opened and the outlet check valve is closed. The down-stroke generates the pressure at the liquid side. The inlet check valve is closed and the outlet check valve is opened by the generated pressure. SUNCENTER liquid pumps cycle automatically, where the pressure is built up the numbers of cycles slow down, the pump stops automatically when the output pressure forces are equal. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump performance can be affected by a number of conditions, such as freezing of muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air line sizes and dirty filers. Don't reduce the indicated port sizes and consult SUNCENTER for exact flow conditions not shown in charts.

Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump

Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
 
Our main products including:
High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)
 
Product Application
Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.
 
Our service
13 months' free warranty since the purchasing date and free technical support during lifetime


Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump
Suncenter Dggd40 0-320bar Air Driven Chemical Liquid Injection Booster Pump




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO 9001