• Suncenter Air Driven Chemical Injection Pump
  • Suncenter Air Driven Chemical Injection Pump
  • Suncenter Air Driven Chemical Injection Pump
  • Suncenter Air Driven Chemical Injection Pump

Suncenter Air Driven Chemical Injection Pump

Max.Capacity: <50 L/min
Pressure Medium: Liquid
Certification: CE
Theory: Reciprocating Type
Structure: Piston Pump
Fuel: Air Driven
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DGGD64
Material
Stainless Steel
Standard or Non
Standard
Power
Pneumatic
Boost Ratio
64:1
Certificate
Ce RoHS
Transport Package
1 Set/Case by Plywood Case
Trademark
SUNCENTER
Origin
China
Production Capacity
100 Sets/Month

Product Description

Suncenter Air Driven Chemical Injection Pump


MOQ:1 Set
Brand Name:SUNCENTER
Certificate:ISO/CE/SGS
Warranty:13 Months
Packaging:by Plywood case
Shipping Port: Shenzhen/Hongkong Payment: T/T,Western Union,Credit card.
Transaction method:EXW,FOB,DDP,CIF,CFR
Place of Origin:Guangdong Province, China (Mainland)
Delivery Time:Within 10-15 working days after received deposit.

Compressed Air Driven Liquid Booster Pump-DGM/DGG/DGGD Series

We offer the most complete range of Air driven liquid pump models in the industry measured for:

A. Capability of ultimate pressure, flow or output horsepower.
B. Compatibility with a broad variety of liquids, such as oil, water and chemical applications.


SUNCENTER pumps are air driven at a drive air pressure of 1bar to 8bar (14.5 psi to116 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.  

Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.  

SUNCENTER pumps are self priming. In general it is not necessary to use an air line lubricator.  The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction effect, the inlet check valve is opened and the outlet check valve is closed. The down-stroke generates the pressure at the liquid side. The inlet check valve is closed and the outlet check valve is opened by the generated pressure. SUNCENTER liquid pumps cycle automatically, where the pressure is built up the numbers of cycles slow down, the pump stops automatically when the output pressure forces are equal. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump performance can be affected by a number of conditions, such as freezing of muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air line sizes and dirty filers. Don't reduce the indicated port sizes and consult SUNCENTER for exact flow conditions not shown in charts.

Applications include:  
Pressure testing
Burst(Hydrostatic) testing
Work holding/power clamping
Jacking/lifting
Valve actuator control
Hydraulic cylinder actuation
Press safety overload devices
Roller tensioning
Metering
Precision lubrication and spraying
Liquefied gas transfer    


Key features include:  
Compressed Air driven - no electricity required (connect to normal air compressor)
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar
No airline lubricator required
Pressures to 640Mpa (6400 bar)  
Wide range of models with different ratios
Built-in-cooling on most models
Easy to install, operate and maintain
Best price / performance ratio
No heat, flame or spark risk and explosion proof
Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant

DGGD Series Liquid Pumps(Double acting, single air drive head) They are characterized by the same features as the DGG pumps single acting, single air drive head types,  but they have less pulsations and deliver approx. 50 % more flow.
Suncenter Air Driven Chemical Injection Pump
Suncenter Air Driven Chemical Injection Pump
The outlet liquid pressure=Driven air pressure*boost ratio In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

How to Select Suncenter Air Driven Liquid Boosters/Systems?
In order to choose suitable liquid booster pump or systems for you, please kindly reply us the following questions:
1.What is the liquid you want to booster?  
2. What outlet liquid pressure do you want?(    )bar  
3. What driven air pressure (of your air compressor) can you offer?(    )bar, Because our booster is completely air operated and no need any electricity  
4. What outlet liquid flow rate do you need?(    )L/min




Suncenter Air Driven Chemical Injection Pump System Suncenter Air Driven Chemical Injection Pump

 Equipment characteristics:
1.    Equipped with high quality pneumatic chemical reagent injection pump, can easily achieve the output pressure and flow of any adjustable, controllable;
2.The contact liquid section is stainless steel, strong corrosion resistance, suitable for a variety of chemical reagents; (also can use the gas system)
3.It can be used in a variety of pressure level of the wellhead, the system with the function of the pressure starting;
4.chemical reagent injection system output pressure is high, 6.0-640 MPa is arbitrary, the system has to stop working under the set pressure;
5.advanced technology, reasonable structure design. The features of small size, light weight, beautiful appearance;
6.by air/gas driven, no need to use electricity, there will be no spark generated, safe explosion-proof;


     
    
    Suncenter Air Driven Chemical Injection Pump

    
 Pneumatic chemical reagent injection pump system-DLS series

The hottest selling Model C cabinet

The standard chemical injection pump system including following parts:
Air -driven liquid booster pump (DGG/DGGD two series for choosing)
Stainless steel (carbon steel) material cabinet (Three models for choosing)
F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)
Driven air switch (Pump starting switch), driven air pressure gauge, chemical(water) tank
Liquid inlet/outlet switch, high pressure liquid guage, unloading valve, interconnecting pipes etc.
And we could also customize it according to clients' special requirement.

 


Suncenter Air Driven Chemical Injection Pump

 


DLS-GD series Technical specification
Model    Pressure Ratio    Driven air pressure PL     Formula to calculate outlet pressure    MAX Outlet
Pressure(bar)*    Driven 
air inlet    port 

DLS-GD series Technical specification
Model Pressure Ratio Driven air pressure PL Formula to calculate outlet pressure MAX Outlet
Pressure(bar)*
Driven
air inlet    port
 
High pressure Outlet port MAX Flow
(L/min)**
DLS-GD6 6:1 3-8 bar 6XPL 48 G 1/2 NPT/ZG 48.60
DLS-GD10 10:1 3-8 bar 10XPL 80 G 1/2 NPT/ZG 30.61
DLS-GD16 16:1 3-8 bar 16XPL 128 G 1/2 NPT/ZG 19.73
DLS-GD28 28:1 3-8 bar 28XPL 224 G 1/2 NPT/ZG 11.30
DLS-GD40 40:1 3-8 bar 40XPL 320 G 1/2 NPT/ZG 7.69
DLS-GD64 64:1 3-8 bar 64XPL 512 G 1/2 NPT/ZG 4.94
DLS-GD80 80:1 3-8 bar 80XPL 640 G 1/2 NPT/ZG 3.96
DLS-GD100 100:1 3-8 bar 100XPL 800 G 1/2 NPT/ZG 3.13
DLS-GD130 130:1 3-8 bar 130XPL 1040 G 1/2 NPT/ZG 2.40
DLS-GD175 175:1 3-8 bar 175XPL 1400 G 1/2 NPT/ZG 1.81
DLS-GD255 255:1 3-8 bar 255XPL 2040 G 1/2 NPT/ZG 1.23
DLS-GD400 400:1 3-8 bar 400XPL 3200 G 1/2 NPT/ZG 0.79


Suncenter Air Driven Chemical Injection Pump



Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
 
Our main products including:
High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)
 
Product Application
Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.
 
Our service
13 months' free warranty since the purchasing date and free technical support during lifetime

Suncenter Air Driven Chemical Injection Pump



Suncenter Air Driven Chemical Injection Pump

Suncenter Air Driven Chemical Injection Pump
Suncenter Air Driven Chemical Injection Pump
Suncenter Air Driven Chemical Injection Pump
Suncenter Air Driven Chemical Injection Pump

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO 9001