Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing

Max.Capacity: <50 L/min
Pressure Medium: Liquid
Certification: CE, ISO
Standard or Non: Standard
Theory: Reciprocating Pump
Power: Pneumatic
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DGGD64
Structure
Piston Pump
Usage
Air Driven
Material
Stainless Steel
Certificate
CE RoHS
Boost Ratio
64:1
Max Testing Pressure
512bar
Transport Package
1 Set/Case by Plywood Case
Trademark
SUNCENTER
Origin
China
Production Capacity
500 Sets/Month

Product Description

Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing
We offer the most complete range of Air driven liquid pump models in the industry measured for:
  1. Capability of ultimate pressure, flow or output horsepower.
  2. Compatibility with a broad variety of liquids, such as oil, water and chemical applications.
SUNCENTER pumps are air driven at a drive air pressure of 1bar to 8bar (14.5 psi to116 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.

Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing
Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.


Applications include:
 
  1.  Pressure testing
  2.  Burst(Hydrostatic) testing
  3.  Work holding/power clamping
  4.  Jacking/lifting
  5.  Valve actuator control
  6.  Hydraulic cylinder actuation
  7.  Press safety overload devices
  8.  Roller tensioning
  9.  Metering
  10.  Precision lubrication and spraying
  11.  Liquefied gas transfer


Key features include:
 
  1. Compressed Air driven - no electricity required (connect to normal air compressor)
  2. In order to extend the lifetime of the pump, the driving air pressure should
not be higher than 8 bar
  1. No airline lubricator required
  2. Pressures to 640Mpa (6400 bar) 
  3. Wide range of models with different ratios
  4. Built-in-cooling on most models
  5. Easy to install, operate and maintain
  6. Best price / performance ratio
  7. No heat, flame or spark risk and explosion proof
  8. Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constan

DGM Series Liquid Pumps(Single acting, single air drive head)
  1. They have aluminum bodies, with oxidation treatment and wetted materials of carbon steel or stainless steel, which depending on different service liquid. Material of stainless steel, making them an excellent choice of water application.
  2. Portable design.
  3. High quality seals, long service life available
  4. Easy to install, operate and maintenance.
  5. Explosion proof and no electrical power required.


Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing

 
Model Pressure  Boost Ratio Driven air pressure PL Formula to calculate outlet pressure MAX Outlet
Pressure(bar)*
Liquid inlet Connection Liquid outlet Connection MaxFlow rate(L/min)**
DGM1 1:1 2-8 bar 1XPL 8 NPT1 NPT1/2 20.50
DGM4 4:1 2-8 bar 4XPL 32 NPT1 NPT1/2 15.36
DGM10 10:1 2-8 bar 10XPL 80 NPT3/4 NPT1/2 7.15
DGM16 16:1 2-8 bar 16XPL 128 NPT /2 NPT 1/2 4.59
DGM30 30:1 2-8 bar 30XPL 240 NPT 1/2 NPT 3/8 2.53
DGM44 44:1 2-8 bar 44XPL 352 NPT 3/8 NPT 3/8 1.41
DGM64 64:1 2-8 bar 64XPL 512 NPT 3/8 NPT 3/8 0.95
DGM100 100:1 2-8 bar 100XPL 800 NPT 3/8 NPT 3/8 0.64
DGM170 170:1 2-8 bar 170XPL 1360 NPT 3/8 M14*1.5 0.37

The outlet liquid pressure=Driven air pressure*boost ratio
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar
DGG Series Liquid Pumps(Single acting, single air drive head)
  1. DGG pumps have aluminum bodies and wetted materials of stainless steel or carbon steel ,which
  depends on different service liquid. Materials of stainless steel, make them an excellent choice
of water application. High quality seals, long service life available.

Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing


Technical specification

 
Model Pressure  Boost Ratio Driven air pressure PL Formula to calculate outlet pressure MAX Outlet
Pressure(bar)*
Liquid inlet Connection Liquid outlet Connection MAX Flow (L/min)
DGG6 6:1 2-8 bar 6XPL 48 NPT1/2 NPT1/2 29.91
DGG10 10:1 2-8 bar 10XPL 80 NPT1/2 NPT1/2 18.84
DGG16 16:1 2-8 bar 16XPL 128 NPT1/2 NPT1/2 12.42
DGG28 28:1 2-8 bar 28XPL 224 NPT1/2 NPT1/2 7.11
DGG40 40:1 2-8 bar 40XPL 320 NPT1/2 NPT1/2 4.89
DGG64 64:1 2-8 bar 64XPL 512 NPT1/2 NPT3/8 3.08
DGG80 80:1 2-8 bar 80XPL 640 NPT1/2 NPT3/8 2.44
DGG100 100:1 2-8 bar 100XPL 800 NPT1/2 NPT3/8 1.92
DGG130 130:1 2-8 bar 130XPL 1040 NPT1/2 M14X1.5 1.47
DGG175 175:1 2-8 bar 175XPL 1400 NPT3/8 M14X1.5 1.14
DGG255 255:1 2-8 bar 255XPL 2040 NPT1/4 M14X1.5 0.75
DGG400 400:1 2-8 bar 400XPL 3200 NPT1/4 M14X1.5 0.48
DGG510 510:1 2-8 bar 510XPL 4080 NPT1/4 M14X1.5 0.65
DGG800 800:1 2-8 bar 800XPL 6400 NPT1/4 M14X1.5 0.42

The outlet liquid pressure=Driven air pressure*boost ratio
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

DGGD Series Liquid Pumps(Double acting, single air drive head)
They are characterized by the same features as the DGG pumps single acting, single air drive head types,
but they have less pulsations and deliver approx. 50 % more flow.


Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing



Technical specification
 
Model Pressure  Boost Ratio Driven air pressure PL Formula to calculate outlet pressure MAX Outlet
Pressure(bar)*
Liquid inlet Connection Liquid outlet Connection MAX Flow (L/min)**
DGGD4 4:1 2-8 bar 4XPL 32 NPT1/2 NPT1/2 70.00
DGGD6 6:1 2-8 bar 6XPL 48 NPT1/2 NPT1/2 48.60
DGGD10 10:1 2-8 bar 10XPL 80 NPT1/2 NPT1/2 30.61
DGGD16 16:1 2-8 bar 16XPL 128 NPT1/2 NPT1/2 19.73
DGGD28 28:1 2-8 bar 28XPL 224 NPT1/2 NPT1/2 11.30
DGGD40 40:1 2-8 bar 40XPL 320 NPT1/2 NPT3/8 7.69
DGGD64 64:1 2-8 bar 64XPL 512 NPT1/2 NPT3/8 4.94
DGGD80 80:1 2-8 bar 80XPL 640 NPT1/2 NPT3/8 3.96
DGGD100 100:1 2-8 bar 100XPL 800 NPT1/2 NPT3/8 3.13
DGGD130 130:1 2-8 bar 130XPL 1040 NPT1/2 M14*1.5 2.40
DGGD175 175:1 2-8 bar 175XPL 1400 NPT3/8 M14*1.5 1.81
DGGD255 255:1 2-8 bar 255XPL 2040 NPT1/4 M14*1.5 1.23
DGGD400 400:1 2-8 bar 400XPL 3200 NPT1/4 M14*1.5 0.79

The outlet liquid pressure=Driven air pressure*boost ratio
In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar



Suncenter DLS Series Pneumatic (Air driven) Liquid Booster System
Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing

Suncenter- DLS Series Pneumatic(Air driven) Hydraulic Power Packs
SUNCENTER- Hydraulic power packs(Liquid pump system) are compact and delicacy solution tailored to customer specific requirements with air driven liquid pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.
To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. SUNCENTER Hydraulic power packs are available with wide range of pressure ratios make these series of pumps ideal for powering a variety of oil/hydraulic operations. The maximum operating pressure up to 640 MPa.
Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing

As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven liquid pump have to be equipped with the air control unit combined filter and water separator, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.

The desired operating pressure can be attained by adjusting the driving air pressure. When the driving air pressure and the output pressure reach the balance, the pump stops filling pressure and the output pressure stays at the preset value. This hydraulic unit can be used for all kinds of pressure testing and test tools for research and test institutes or for other functions requiring a determined pressure. 



Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing


Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
 
Our main products including:
High-Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)
 
Product Application
Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.
 
Our service
13 months' free warranty since the purchasing date and free technical support during lifetime

Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic TestingSuncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic TestingSuncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing
Suncenter Pneumatic Water Pressure Test Booster Pump for Pipe Valves Hose Hydrostatic Testing


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO 9001