Max.Capacity: | >400 L/min |
---|---|
Pressure Medium: | Gas |
Certification: | CE, ISO |
Application: | Increasing Gas Pressure, Transferring and Filling |
Boost Ratio: | 25:1 |
Boost Medium: | Nitrogen/ Argon/Helium/Hydrogen/CO2/Oxygen or Othe |
Customization: |
---|
Suppliers with verified business licenses
Model | Pressure boost ratio | Min. gas Inlet pressure PA (bar) |
Max.gas Inlet pressure PA (bar) |
Max. gas outlet pressure PB (bar) |
Driven air pressure PL |
Formula to calculate gas outlet pressure PB |
Connection: Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min) |
DGT25 | 25:1 | 0.1 | 10 | 200 | 2-8 bar | 25XPL+3.5XPA | 3/8/ 1/4 | 136(at PA of 8 bar ) |
DGT40 | 40:1 | 0.1 | 10 | 320 | 2-8 bar | 40XPL+ 6XPA | 3/8/ 1/4 | 124(at PA of 8 bar ) |
DGT10/60 | 10:1/60:1 | 0.1 | 10 | 480 | 2-8 bar | 60XPL+6X PA | 3/8/ 1/4 | 84(at PA of 8 bar ) |
DGT25/60 | 25:1/60:1 | 10 | 25 | 480 | 2-8 bar | 60XPL+2.5XPA | 3/8/ 1/4 | 80(at PA of 15 bar ) |
DGT100 | 100:1 | 0.1 | 10 | 800 | 2-8 bar | 100XPL+10XPA | 3/8/ M14*1.5 | 63(at PA of 8 bar ) |
Suppliers with verified business licenses